No products
Control unit SG1577, Suitable for...
Among Eberspacher Airtronic heater parts in our catalogue on our site you can buy all the following D2 spares:
Glow Plugs - The glow plug ensures that the fuel mixture ignites when the heater starts up.
Glow Plug Screens with Installation Tool-An essential part of the fuel distribution and burning system for Airtronic heater. It is often overloo...
Among Eberspacher Airtronic heater parts in our catalogue on our site you can buy all the following D2 spares:
Glow Plugs - The glow plug ensures that the fuel mixture ignites when the heater starts up.
Glow Plug Screens with Installation Tool-An essential part of the fuel distribution and burning system for Airtronic heater. It is often overlooked when carrying out heater maintenance. Clean and effective glow plug screen can help prolong glow plug life and encourage a better burning process.
Eberspacher brand fuel pumps for Airtronic d2 are a combined supply, dosing and shut-off system to provide the heater with fuel from the car’s fuel tank.The fuel pump is a combined system of supplying, metering and blocking the fuel supply.. All processes occurring in Airtronic are reliably controlled by electronic control unit, and when any deviation of normal system parameters occurs, immediately happens blockage of the start or the immediate shutdown of the fuel pump. Program incorporated in the control unit provides control of 33 parameters. If within 90 seconds after the start of the fuel pump operation there is no ignition,Airtronic will attempt to restart.
If after the next 90 seconds the ignition pump does not work again,the heater goes into emergency mode, i.e., the fuel supply is turned off and during approximately 4 minutes run-down of the fan takes place. After a certain amount of unsuccessful starts blocking of the control unit occurs. If the flame disappears during operation, the heater tries to restart. If ignition does not occur after 90 seconds after the fuel pump resumes operationor if the ignition occurs, but after 15 seconds it goes out again, the device goes into emergency mode, i.e., the fuel supply stops and for about 4 minutes occurs inertial run of the fan. Emergency shutdown can be deactivated by fast off and on. Turning off and on should not be repeated more than twice.
Control units - provide control of the heater in conjunction with the control panel. It perform the following functions such as switching the heater on and off by command from the control panel; Initial diagnostics (health check) of the heater units at start; diagnostics of heater units during all operation time.
Flame and overheating sensors - flame sensor for the autonomous heater is required to monitor the heater's temperature and to switch on the alarm mode in case of overheating or flame.
Air blower is required to supply air to the combustion chamber of the Eberspacher heater.
Clamp 11 mm, Suitable for Eberspacher heaters, Full list of aplicability in the main description.
Clamp 9mm, Suitable for Eberspacher heaters, Full list of aplicability in the main description.
Grommet for lower casing, Suitable for the following Eberspacher Airtronic Heaters: Airtronic D2,Airtronic D4,Airtronic D5.
Hose Clamp 20-35mm Suitable for Eberspacher heaters - 102067020032
Eberspacher Grommet Fuel Inlet, Genuine Eberspacher product , Suitable for the following Eberspacher Heaters: Eberspacher Heater Airtronic D2, Eberspacher Heater Airtronic D4.
Eberspacher base gasket seal, Suitable for the following Eberspacher Heaters,Eberspacher Heater Airtronic D2,Eberspacher Heater Airtronic D4.
Bolt M6x100 Suitable for Eberpsacher heaters
Grid candles Airtronic D2 / D3 / D4 / B4 M8 / M10 / M12 with guid,Genuine Eberspacher product,Full list of aplicability in the main description.
Lower Casing suitable for Eberspacher Heater Airtronic D2.
Among Eberspacher Airtronic heater parts in our catalogue on our site you can buy all the following D2 spares:
Glow Plugs - The glow plug ensures that the fuel mixture ignites when the heater starts up.
Glow Plug Screens with Installation Tool-An essential part of the fuel distribution and burning system for Airtronic heater. It is often overloo...
Among Eberspacher Airtronic heater parts in our catalogue on our site you can buy all the following D2 spares:
Glow Plugs - The glow plug ensures that the fuel mixture ignites when the heater starts up.
Glow Plug Screens with Installation Tool-An essential part of the fuel distribution and burning system for Airtronic heater. It is often overlooked when carrying out heater maintenance. Clean and effective glow plug screen can help prolong glow plug life and encourage a better burning process.
Eberspacher brand fuel pumps for Airtronic d2 are a combined supply, dosing and shut-off system to provide the heater with fuel from the car’s fuel tank.The fuel pump is a combined system of supplying, metering and blocking the fuel supply.. All processes occurring in Airtronic are reliably controlled by electronic control unit, and when any deviation of normal system parameters occurs, immediately happens blockage of the start or the immediate shutdown of the fuel pump. Program incorporated in the control unit provides control of 33 parameters. If within 90 seconds after the start of the fuel pump operation there is no ignition,Airtronic will attempt to restart.
If after the next 90 seconds the ignition pump does not work again,the heater goes into emergency mode, i.e., the fuel supply is turned off and during approximately 4 minutes run-down of the fan takes place. After a certain amount of unsuccessful starts blocking of the control unit occurs. If the flame disappears during operation, the heater tries to restart. If ignition does not occur after 90 seconds after the fuel pump resumes operationor if the ignition occurs, but after 15 seconds it goes out again, the device goes into emergency mode, i.e., the fuel supply stops and for about 4 minutes occurs inertial run of the fan. Emergency shutdown can be deactivated by fast off and on. Turning off and on should not be repeated more than twice.
Control units - provide control of the heater in conjunction with the control panel. It perform the following functions such as switching the heater on and off by command from the control panel; Initial diagnostics (health check) of the heater units at start; diagnostics of heater units during all operation time.
Flame and overheating sensors - flame sensor for the autonomous heater is required to monitor the heater's temperature and to switch on the alarm mode in case of overheating or flame.
Air blower is required to supply air to the combustion chamber of the Eberspacher heater.