Control Unit SG 1577 24v for Webasto TH90S (Diesel) - 9025554A View larger

Control Unit SG 1577 24v for Webasto TH90S (Diesel) - 9025554A

New product

Control Unit SG 1577 24v,

  • Genuine Webasto product,
  • Suitable for Thermo 90S,

Please note 24v only,

Diesel only.

More details

$478.34

Add to wishlist

Data sheet

ManufacturerWebasto (Germany)
Fuel typeDiesel
Voltage24 V

More info

Kit to replace the control unit heater Thermo90S

SG 1577

Old block

New kit

12V gasoline

90253

9025598

12V diesel

88545

9025599

24V diesel

89093

9025554

Replacement kits include:

  • control unit 1pc.
  • cable harness adapter 1pc.
  • set clamp seal 1pc.
  • set cap 1pcs.
  • assembly instructions 1pc.

Caution: Replacement kits can only be used for Thermo90S

The control unit and cable harness adapter are designed to be replaced in standard heaters.

When replacing, pay attention to the color-coded connectors!

Note : the wiring harnesses for the cabin heater and fuel pump remain the same.

Pos.

Knot

Wire colors

X1

Supercharger

son. / cor.

X2

Glow pin

yellow / box

X3

Metering pump

son. / cor.

X4

Circulation pump

black / black

X5

Temperature sensor

zel. / zel.

X6

Flame sensor

ser./sir.

X7

overheat protection

fiol. / fiol.

X8

Wire harness connector

various

Set clamp-seal:

If the installation of the control unit is not possible in the standard position, the mounting position can be changed with the help of a clamp and seal.

Seal must be replaced. The mounting position of the Thermo90ST control unit can be any. The position presented performs the protection type 6K9K.

Set of plugs for the circulation pump

The cap is designed for external control of the circulating pump. External control of the circulating pump via the control unit is not possible. To connect an external control of the circulating pump, the plug is turned on instead of the pump connector into the control unit (connector X4). In this case, the pump can be controlled by an external source. Diagnostic polling in the control unit is disabled.

Attention : the external control of the circulating pump must be chosen in such a way that the pump will function during the whole time of the heater operation, including during the purge period. Electrical connections must be leak tight.

Note:

  • Please take into account when replacing additional information from the instructions for installation, operation and repair;
  • When installing the control unit not on the preheater, its reverse wall should not be insulated, as It is a heat sink from the elements of the unit.
  • When installing, pay attention to sufficient distance to heat sources.
  • Repairs should only be carried out by certified, certified personnel.

Comments ()

Reviews

Write a review

Control Unit SG 1577 24v for Webasto TH90S (Diesel) - 9025554A

Control Unit SG 1577 24v for Webasto TH90S (Diesel) - 9025554A

Control Unit SG 1577 24v,

  • Genuine Webasto product,
  • Suitable for Thermo 90S,

Please note 24v only,

Diesel only.

30 other products in the same category: