No products
New product
Glow pin 24v,
Manufacturer | Webasto (Germany) |
Voltage | 24 V |
When starting the heater, the glow pin ignites the fuel-air mixture. The heating pin is an electrical resistance and is located in the burner at a short distance from the evaporating element.
When checking the glow pin with a digital multimeter, the parameter values must be within the following limits. Pins differ in color marking:
Pin pin: 12V (red) 24V (green) Resistance at 25 ° C: 0.3-0.6 ohm 1.3-1.44 ohm Test current: <5 mA <5 mA
1. Remove the heater.
2. Remove the air blower.
3. Remove the screws and washers.
4. Unscrew the nuts and pull out the retaining bar.
5. Pull the seals out of the flame tube body.
6. Pull out the seal and burner, as well as the divider from the flame tube.
7. Remove the flame sensor and the heat pin from the burner body.
8. Visually assess the condition of the burner.
9. To carry out work on the dismantled nodes.
1. Install the air divider on the burner body.
2. Carefully insert the flame sensor and the heat pin into the burner body and insert the seals into the flame tube body.
3. Insert the burner and gasket into the body of the flame tube.
CAUTION! Ensure that the wiring of the filament pin and flame sensor is routed as shown in the figure.
4. Install the insulation on the locking bar and install the bar.
5. Secure the locking bar with nuts. Tighten the nuts to 3 Nm ± 10%.
6. Secure the fuel line with the screw and washer. Tightening torque 3 Nm ± 10%.
7. Install air blower.
8. Connect the electrical connectors.
9. Install the heater.